DTHC Series

Image DTHC Series

Recognized version shown

The new DTHCr with 90% to 99% efficiency is really a new era in the gas heater industry. Its condensing capabilities not only offers 18% superior combustion efficiency for the end user, it provides a system that can accommodate static fan pressure.

  • High Efficiency
  • VAV Capability
  • Low PD Cabinet
 

Features

  • 90% to 99% efficiency @ 70°F (21°C) S.T.
  • High turndowns from 15:1 to 31:1
  • Very low CO levels
  • Low PD heat exchanger
  • High air flow (HAF) even lower PDs
  • 304L stainless steel heat exchanger
  • Plenum fan ready
  • Close coupled DWDI fan ready
  • Integrated downturn plenum arrangement

Standard

  • 10 capacities from 394 to 1688 MBH output
  • Only 4 cabinet sizes
  • 7” inlet gas pressure
  • High altitude installation
  • 2-10 Vdc or 4-20 ma input signaler
  • Left or right hand controls
  • Category IV venting

Optional

  • High Air Flow (HAF) low static
  • 316L SS Heat exchanger
  • FM or IRI gas train options
  • Construction for 32˚F (0˚C), -4˚F (-20˚C) or -40˚F (40˚C)
  • Indoor or outdoor enclosures
  • Separated combustion air supply
  • 316SS wall and components
  • Propane gas
  • Painted gas train
  • Customized Category IV chimneys
  • VAV capabilities to 20%
  • MODBUS communication
  • Condensate drain kit
  • Condensate neutralizer kit

The new condensing heater is available in both listed or recognized versions for user friendly incorporation in an HVAC system or OEM equipment.

Image DTHC listed component

DTHC listed component

Image DTHCr recognized component

DTHCr recognized component

Image DTHC text 1

The condensing heat exchanger is a 4 pass design having a water drop-shaped drum with double axis dimpled tubes. It is 100% made of 304L stainless steel to resist corrosion from condensation of the flue gases. The efficiency achieved can be as high as 99%.

Microstep combustion monitoring is achieved with a PLC and ECM motor providing precise combustion characteristics. The result is high turndown ratios from 15:1 to 31:1 and thermal efficiencies from 90% to 99% with 0 PPM of CO at full fire.

Image part DTHC text 2
Available with 5 different control enclosure and combustion air inlet options.
  • Image control enclosure 1

    Environmental combustion air to 32°F (0°C)

  • Image control enclosure 1

    Ducted combustion air to -40°F (-40°C)

  • Image control enclosure 1

    For indoor installation, ducted combustion air to -40°F (-40°C)

  • Image control enclosure 1

    For outdoor installation, combustion air with hood to -4°F (-20°C)

  • Image control enclosure 1

    For outdoor installation, combustion air with hood to -40°F (-40°C)